Used digital oscilloscope
I have found results from4000+products and1000+suppliers aboutUsed digital oscilloscope
Rigol Mso2102A-S Mso2202A-S Mso2302A-S Digital Oscilloscope
Automatic Digital Dual Channel Oscilloscope with 300MHz Bandwidth
Automatic Oscilloscope 2 in 1 Dual Channel Analog Bandwidth 1gsa/S Portable Digital Storage
Digital 2 Channel Oscilloscope 100MHz 200MHz Bandwidth Large Screen Phosphor Oscilloscope 1GS/s
Fnirsi Dpox180h 180MHz3db 2in1function Signal Generator Handheld Dual Channel Digital Oscilloscope
Fnirsi 2c23t Latest 3 in 1 2CH Handheld Digital Storage Oscilloscope
12-Bit High Resolution T3dso3000HD Digital Oscilloscope Mixed Signal Analysis
Hantek Dso5102p USB 1gsa/S 100MHz 7'' TFT Digital Oscilloscope 40K 2CH 2chanel
Keysight Msox4024G Mixed Signal Oscilloscope 200 MHz 4 Digital Channels
R&S Precision Fsl18 Spectrum Analyzer Digital Oscilloscope for Detailed Testing
Digital Oscilloscope 250MHz Bandwidth 4 CH Channel 1gsa/S Sampling Rate USB2.0 Interface
Msox3054G Mixed Signal Oscilloscope: 500 MHz, 4 Analog Plus 16 Digital Channels
Digital Storage Oscilloscopes SDS7000A Series
Digital Storage Oscilloscopes SDS6000A Series with Bandwidths of 2GHz, 1 GHz, 500 MHz for Multiple Signal Timing Test
Educational Digital Storage Oscilloscope 50MHz 2 Channels for University and College Labs Testing
Sourcing guidance for Used Digital Oscilloscope
What are the key technical specifications to verify when purchasing a used digital oscilloscope?
When sourcing used equipment, you must prioritize Bandwidth (ensure it is at least 3 to 5 times the highest frequency of your signals) and Sample Rate (look for a real-time sample rate of at least 4x the bandwidth). Additionally, verify the Memory Depth to ensure long waveforms can be captured without losing detail, and check the Number of Channels (typically 2 or 4) to match your specific testing requirements.
How can I ensure the functional integrity and accuracy of a second-hand unit?
Request a Self-Test and Calibration Report from the supplier. A professional seller should provide a video showing the unit passing its internal diagnostic routines. Check for Screen Burn-in or dead pixels on the display, and ensure all Physical Knobs and Buttons are responsive. It is highly recommended to ask for a Probe Compensation Test video to verify the input frontend is not damaged.
What compliance and safety standards should a used oscilloscope meet for international trade?
Ensure the device carries the CE Mark for European markets or meets UL/ETL standards for North America. Since these are electronic devices, verify compliance with RoHS (Restriction of Hazardous Substances). For used equipment, specifically ask for a Safety Leakage Current Test to ensure the chassis is properly grounded and safe for laboratory use.
Is it economically feasible to buy used high-end brands versus new entry-level models?
Purchasing used units from premium brands like Tektronix, Keysight (Agilent), or Rohde & Schwarz often provides better Signal Integrity and Triggering Capabilities than new low-cost alternatives. However, you must factor in the Cost of Recalibration (typically $200-$500) and the lack of a manufacturer warranty. If the price is more than 60-70% of a new equivalent model, a new unit with a warranty may be a better long-term investment.
Cross-Border Procurement Risks and Strategies for Used Electronics
What are the primary risks when importing used test equipment across borders?
The biggest risks include Hidden Hardware Defects that are not visible in photos and Shipping Damage to sensitive CRT or LCD screens. Furthermore, some countries have strict E-waste Import Regulations; you must ensure the HS Code (typically 9030.20) is correctly declared as 'Used Equipment' rather than 'Waste' to avoid customs seizure.
How should I negotiate with suppliers on Made-in-China.com for used goods?
Focus your negotiation on Warranty Periods (aim for at least 3-6 months) and the Inclusion of Accessories. Used oscilloscopes often lack original probes; insist on the supplier including High-Quality Passive Probes and a power cord. Ask for a Batch Discount if purchasing more than 3 units, as shipping costs per unit decrease significantly with volume.
What transaction security measures should be taken for high-value used electronics?
Always use Secured Payment Terms offered through the platform to ensure funds are only released after you confirm receipt and basic functionality. Request a Pre-shipment Inspection (PSI) or a detailed 'Golden Sample' video where the supplier shows the Serial Number of the specific unit being packed and shipped to you.
What is the best shipping method for sensitive digital instruments?
Due to the sensitivity of the internal oscillators and screens, use Express Couriers (DHL, FedEx, or UPS) with 'Fragile' labeling. Ensure the supplier uses Double-Walled Corrugated Boxes with at least 5cm of high-density foam padding on all sides. For bulk orders, Air Freight is safer than Sea Freight to minimize prolonged exposure to humidity and vibration.