SourcingAI

Radar level transmitter

I have found results from10000+products and5000+suppliers aboutRadar level transmitter

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Armour Type
Contact: Contactless
Output Signal Type: Analog Type
Production Process: Normal Wirewound
Feature: Corrosion Resistant
IP Rating: IP67
Certification: CE
Customized: Customized
Principle: Vacuum Sensor
Range: >0-30m
Measurement Accuracy: ±3mm
Accuracy: 0.1%
Liquid Level Transmitter
All in One
Warranty: 1 Year
Material: SS360L
Process Temperature: -40~250℃
Display Type: LCD
Structure Design: Flange Type
Pressure Range: High Pressure
Accuracy Grade: 0.2G
Contact: Contact
Output Signal Type: Digital Type
Production Process: Integration
Low Temperature Resistant
Feature: Conductor
IP Rating: IP68
IP Rating: IP65
Certification: RoHS
Customized: Non-Customized
Principle: Magnetic Sensors
Principle: Gas Sensors
Range: 0-30m
Measurement Accuracy: ±5mm
Accuracy: 0.25%
Accuracy: 0.2%
Kind: Static Pressure
Kind: Radar
Structure: Split Type
Warranty: 3 Year
Material: Stainless Steel
Material: SS304
Material: Metal
Material: Plastic
Process Temperature: -20℃~80℃
Process Temperature: -40~120℃
Display Type: LED
Structure Design: Screw Type
Structure Design: Input Type
Pressure Range: Atmospheric pressure
Accuracy Grade: 0.1G

Sourcing guidance for Radar Level Transmitter

What are the key technical differences between 26GHz and 80GHz radar level transmitters?

The primary difference lies in the beam angle and precision. 80GHz radar offers a much narrower beam (typically 3° to 6°), which minimizes interference from internal tank structures like agitators or ladders. It provides millimeter-level accuracy (±1mm to ±2mm) and is ideal for small vessels or solids. 26GHz radar has a wider beam and is generally more cost-effective for large-scale liquid storage tanks where internal obstructions are minimal.

How do I select the correct antenna type for different media?

Antenna selection depends on the chemical properties and state of the medium. For corrosive liquids, choose a PTFE-sealed horn or rod antenna to prevent chemical attack. For high-temperature or high-pressure environments, a stainless steel horn antenna with a ceramic seal is required. If measuring solids or powders, a parabolic antenna or a horn with a dust cover is recommended to prevent signal attenuation caused by dust accumulation.

What compliance standards are mandatory for international industrial sourcing?

For hazardous environments, ensure the device has ATEX or IECEx explosion-proof certification. For pressure vessel integration, compliance with the Pressure Equipment Directive (PED) is vital. Additionally, look for SIL 2/3 (Safety Integrity Level) ratings if the transmitter is part of a safety instrumented system to prevent tank overfill. Ingress Protection (IP67 or IP68) is a must for outdoor or wash-down environments.

How does the Dielectric Constant (Dk) affect the procurement choice?

The Dielectric Constant of the medium determines the strength of the reflected signal. Media with a low Dk (e.g., oils, hydrocarbons) reflect less energy, requiring high-sensitivity sensors or Guided Wave Radar (GWR). For media with a high Dk (e.g., water-based liquids), standard Non-Contact Radar is highly effective. Always provide the supplier with the specific Dk value to ensure the transmitter's signal-to-noise ratio is sufficient.

Cross-Border Procurement Strategy for Precision Instrumentation

How can I mitigate the risk of receiving damaged or miscalibrated instruments?

Request a Factory Acceptance Test (FAT) report and a Calibration Certificate for every unit before shipment. Use third-party inspection services to verify the protective packaging, as radar lenses are fragile. Ensure the supplier uses anti-static and shock-absorbent materials to prevent electronic failure during long-haul transit.

What are the best practices for negotiating with technical suppliers on Made-in-China.com?

Focus on long-term technical support rather than just the initial unit price. Negotiate for extended warranties (24 months instead of 12) and request free spare parts (like gaskets or display modules). For bulk orders, ask for tiered pricing where the discount increases by 10-15% once the volume exceeds 50 units.

How should I handle international shipping and customs for electronic sensors?

Ensure the supplier provides the correct HS Code (typically 9026.10) to avoid customs delays. For urgent projects, use Air Freight (DAP/DDP terms) to minimize port congestion risks. Verify that the Country of Origin (COO) certificates are included to benefit from potential trade agreements or to comply with local import regulations.

What transaction security measures should be taken for high-value industrial orders?

Utilize secured payment systems provided by Made-in-China.com to ensure funds are only released upon proof of shipment. For large-scale projects, consider a Letter of Credit (L/C) or a 30/70 payment structure (30% deposit, 70% after passing pre-shipment inspection) to maintain leverage over product quality.

Related queries