Network analyzer
I have found results from30000+products and10000+suppliers aboutNetwork analyzer
P5025A Keysight Streamline USB Vector Network Analyzer, 26.5 GHz
P5028b Streamline Vector Network Analyzer, 100 kHz to 53 GHz, 4-Port
P9372b Streamline Vector Network Analyzer, 9 kHz to 9 GHz, 2-Port
P5002b Streamline Vector Network Analyzer, 9 kHz to 9 GHz, 2-Port
RMS Voltage Current Harmonic Meter Portable Energy Testing Equipment Power Quality Network Analyzer
Handheld Electric Single Phase Harmonic Network Power Analyser Touch Screen Precision Digital Power Quality Analyzer
P5001b Streamline Vector Network Analyzer, 9 kHz to 6.5 GHz, 2-Port
P5026b Streamline Vector Network Analyzer, 100kHz to 32GHz, 4-Port
Keysight N9935A Network Analyzer for RF Component and Network Characterization
Electrical Network Analyzer Three Phase Power Quality Analyzer Price Power Station
MSA080B Spectrum Analyzer Module with Vector Network Analysis MSA080B-VNA (100kHz to 8GHz)
Keysight E5071c E5071b Ena Vector Network Analyzer 9 kHz to 20 GHz
Keysight E8363c Pna Microwave Network Analyzer 10 MHz-40 GHz
Keysightn5241b Pna Microwave Network Analyzer 900 Hz/10 MHz to 13.5 GHz
Rohde&Schwarz Znbt20 Vector Network Analyzer 100 kHz to 20 GHz
Keysightn52457b Pna-X Microwave Network Analyzer 900 Hz/10 MHz to 67 GHz
N5234b Pna-L Microwave Network Analyzer 43.5 GHz
Rohde&Schwarz Znl20 Vector Network Analyzer 5 kHz to 20GHz
Keysight E5080A/E5081A Vector Network Analyzers 53GHz
Harmonic Test Device Three Phase Power Quality Analyser Electrical Network Analyzer
Advanced CT/PT Analyzer for Primary Injection Testing in Distribution Networks
High Voltage Switchgear PD Test Set Partial Discharge Analyzer
Partial Discharge Analyzer for transformers, switchgear, cable and GIS
HV HIPOT High Voltage Switchgear PD Test Set Partial Discharge Analyzer GDPD-414
Sourcing guidance for Network Analyzer
What are the key technical specifications to consider when selecting a Network Analyzer for industrial use?
When procuring a Network Analyzer (specifically Vector Network Analyzers or VNA), the most critical specification is the Frequency Range, which must cover your specific application (e.g., 9kHz to 8.5GHz for standard RF components). You must also evaluate Dynamic Range (ideally >120 dB) to ensure measurement sensitivity and Trace Noise (lower than 0.005 dB rms) for high precision. For high-speed production lines, prioritize units with fast sweep speeds (e.g., <10 ms for 201 points) and ensure the device supports multi-port configurations (2-port or 4-port) depending on the complexity of the DUT (Device Under Test).
Which international compliance standards and certifications are mandatory for importing Network Analyzers?
As high-precision electronic test equipment, Network Analyzers must adhere to Electromagnetic Compatibility (EMC) standards such as EN 61326-1. For the North American market, FCC Part 15 compliance is essential, while the European market requires the CE Mark and adherence to the Low Voltage Directive (LVD). Additionally, ensure the supplier provides a Calibration Certificate traceable to international standards like NIST or ISO/IEC 17025, as this is vital for quality audit trails in B2B sectors.
How can a buyer verify the long-term reliability and accuracy of a Network Analyzer from a cross-border supplier?
Reliability is verified through Mean Time Between Failures (MTBF) data and the quality of internal components. Request the supplier to provide stability test reports showing measurement drift over 24 hours. It is highly recommended to choose suppliers on Made-in-China.com who offer Audited Supplier reports, which confirm their manufacturing capabilities and R&D strength. Furthermore, check if the firmware supports remote SCPI command sets, ensuring the hardware can be integrated into automated test environments (ATE) for long-term industrial scaling.
Cross-Border Procurement Strategy for High-Precision Instruments
What are the primary risks when purchasing high-value electronic instruments internationally?
The main risks include shipping damage to sensitive sensors and customs delays due to dual-use technology classifications. To mitigate these, insist on specialized shock-absorbent packaging (double-boxing with foam inserts) and ensure the HS Code (typically 9030.40) is correctly declared. Use Trade Assurance services on platforms like Made-in-China.com to secure your payment until the equipment is delivered and passes initial power-on self-tests (POST).
How should buyers negotiate after-sales support and calibration services with overseas suppliers?
Negotiate for a minimum 2-year warranty and clarify the process for Return Merchandise Authorization (RMA). Since shipping a Network Analyzer back for annual calibration is costly, ask the supplier if they provide remote software updates or if they have authorized local service centers. Requesting a spare parts kit (such as replacement N-type or SMA connectors) during the initial negotiation can significantly reduce future downtime.
What logistics and payment precautions should be taken for high-precision Network Analyzers?
Given the high unit value, use Letter of Credit (L/C) or Escrow payments for large orders to ensure transaction security. For shipping, avoid standard postal services; instead, use reputable air freight couriers (DHL/FedEx/UPS) with full value insurance. Ensure the commercial invoice clearly states the serial numbers of the units to facilitate smooth customs clearance and to prevent issues during potential future re-export for repairs.





























