Lead glass screen
I have found results from200000+products and100000+suppliers aboutLead glass screen
Medical Hospital Customized X Ray Protection Lead Screen
Three Couplet Medical X-ray Lead Shield Screen
Discounted Ls04 Medical Xray Lead Glass Door Barrier Mobile 3 Fold X-ray Lead Glass Window Lead Screen
in-1109 Radiation Screen X-ray Protective Lead Glass Screen X-ray Protective Lead Screen with Window Product
99.99% Lead Roll Plate Sheet Lead Wall Glass Screen for Radiation-Shielding
High Transmittance Lead Glass Lead Screen for Medical Use
Medical Operating Room Movable Lead Screen CT Room Ray Shielding
Factory Customized Free Design Radiation Proof Lead Screen Folding Triple Lead Screen Movable Single Lead Screen
Mobile Single Double Radiology 1 Equivalent 0.5 Visible Lead Screen
Radiation Protection Lead Screen X-ray Lead Screen Ctdr Dental Partition Multi-Link Radiology Single Double Triple
Movable Double Lead Screen for Radiation Protection with Glass
Embedded Lead Glass Radiation Shielding Lead Barrier Lead Screen for Maximum Protection
Radiation Protection Mobile 3mmpb Lead Glass Screen for X Ray Room
3mmpb Mobile Lead Glass Screen for X-ray Security Examination
X-ray Shielding 2mmpb Double Triple Couplets X Ray Protective Lead Screen with Glass
Unobstructed Observation Lead Screen with High Light Transmittance Glass 2mmpb 3mmpb 4mmpb Lead Screen for Cath Lab
Mobile L-Shaped Screen with Lead Glass Viewing Window L-Shape Lead Radiation Screen for Hot-Lab Radioactive Work
Customized L Shielding Screen with Transparent Lead Glass Observation Window L-Shaped Lead Radiation Shield Screen for Hospital
X-ray Radiation Protection Screen with Lead Glass 3mmpb 5mmpb 6mmpb 7mmpb 8mmpb Mobile Lead Screen for Dr Room
Medical L Shielding Screen with Lead Glass Window 40mmpb 30mmpb 10mmpb L-Shape Lead Shield Screen for Interventional Room
Medical Lead Screen with Lead Glass Observation Window 1mmpb 2mmpb 3mmpb 4mmpb Lead Barrier for Medical Institution
Nuclear Medicine L-Shaped Operation Screen with Lead Glass Xray Shielding Mobile Injection Vehicle
Supply Hospital Lead Screen with Lead Glass X-ray Protective Lead Screen with Window
Sourcing guidance for Lead Glass Screen
What are the key technical specifications to consider when selecting a lead glass screen for medical or industrial use?
The most critical specification is the Lead Equivalent (Pb Eq), typically ranging from 0.5mmPb to 3.0mmPb depending on the radiation source (X-ray, CT, or Gamma). You must ensure the glass transparency exceeds 85% to maintain clear visibility for operators. Additionally, for mobile screens, the frame material should be medical-grade stainless steel or powder-coated steel to ensure durability and ease of sterilization.
Which international compliance standards must lead glass screens meet for cross-border trade?
Suppliers should provide certification for IEC 61331-2:2014 (Protective devices against diagnostic medical X-radiation). For the European market, CE Marking is mandatory, while the US market requires FDA registration. Ensure the manufacturer holds an ISO 13485 certification, which specifically governs quality management systems for medical devices.
How can I verify the radiation shielding effectiveness of a lead glass screen before shipment?
Request a Third-Party Radiation Shielding Test Report from the supplier. You should also ask for a Material Safety Data Sheet (MSDS) for the lead glass component. For high-value orders, it is advisable to hire an inspection agency to perform a non-destructive test (NDT) using a radiation meter to confirm there are no 'leaks' or bubbles in the glass that could compromise safety.
What are the structural requirements for mobile lead glass screens in high-traffic hospital environments?
Mobile screens must be equipped with heavy-duty, medical-grade lockable casters to prevent accidental movement during procedures. The center of gravity should be low to prevent tipping, and the handle design should be ergonomic. For fixed installations, ensure the overlap between the lead glass and the lead-lined frame is at least 10-15mm to prevent radiation leakage at the seams.
Cross-Border Procurement & Risk Management for Lead Glass
What are the primary risks associated with shipping lead glass screens internationally?
The primary risk is structural breakage due to the high density and brittleness of lead glass. You must mandate customized fumigated wooden crate packaging with internal shock-absorbing foam and vacuum sealing. Ensure the shipment is marked with 'Fragile' and 'Heavy' icons, and always purchase All-Risk Marine Insurance to cover potential transit damage.
How should I negotiate with suppliers on Made-in-China.com to ensure quality and safety?
Start by requesting a sample of the lead glass (e.g., a 10x10cm block) to test density and clarity. Negotiate a staged payment plan (e.g., 30% deposit, 70% after passing a pre-shipment inspection). Use the Audit Reports available on Made-in-China.com to verify if the supplier is a 'Diamond Member' or a 'Gold Member' with a verified manufacturing facility.
What are the specific customs and logistics considerations for lead-based products?
Lead is a heavy metal and may be subject to environmental regulations in the destination country. Verify the HS Code (typically 7007.19 or 7013.99) with your local customs broker to determine import duties. Due to the extreme weight, Sea Freight (LCL or FCL) is the most economical method, but ensure the floor loading capacity of the delivery vehicle and the final installation site is sufficient.
How can I ensure transaction security when dealing with high-value medical equipment?
Utilize Secured Trading Services provided by Made-in-China.com to protect your funds. Avoid direct transfers to private bank accounts; always use the official corporate account listed on the platform. Conduct a Video Factory Audit to see the production line and the specific batch of goods being prepared for your order.





























