Electromagnetic lock
I have found results from40000+products and10000+suppliers aboutElectromagnetic lock
560kg (1200Lbs) 12V Electromagnetic Lock Glass Electric Double Door Magnetic Lock
Single Door Magnetic Electromagnetic Electric Controlled Lock for Glass Door Access Control
DC12V Waterproof IP68 Outdoor 600kg (1200Lbs) Glass Door Electromagnetic Electro Magnetic Door Lock
Single Door Electromagnetic Lock 280kg 600lbs with LED and Door Sensor
Security Safe Electromagnetic Digital Fingerprint Recognition Smart Door Lock
Krovi F06 Digital Door Lock Hotel Tuya Smart Lock Cylinder Safe Lock Padlock Electromagnetic
Stainless Steel Shell Aluminum Alloy Shell Waterproof Outdoor Electromagnetic Lock
Taiwan Electromagnetic 12V Hotel Door Reinforcement Lock
Em Lock Electromagnetic Lock Electric Controlled Lock Magnetic Lock 12V Lock
UL Factory Supply 280kgs (390Lbs) Magnetic Electromagnetic Electric Controlled Lock
UL Supplier Factory Supplies 350kg (770Lbs) Magnetic Electromagnetic Control Lock
UL Chinamanufacturer Supply 280kgs (600Lbs) 12V/24V Magnetic Electromagnetic Electric Controlled Lock
High-Quality Fail-Safe Electromagnetic Lock with Signal
12V Keyless Electromagnetic Lock with Signal Output Dual-Door Access Control Security System
Dsn-Amz Dsn-Amy Indoor High Voltage Switchgear Cabinet Door Electromagnetic Solenoid Lock
Security Access Control RFID Card Reader Door Lock Electromagnetic Door Lock with Signal Output Function
Asl-2400 1200kg Electromagnetic Lock 12/24VDC Magnetism Shear Lock
Security Safe Electromagnetic Digital Fingerprint Recognition Smart Door Lock
SHMi LY01 Series Electromagnetic Lock for Cabinets, Lockers & Drawers
SHMi 60KG Multi-Pull-Force DC12V/24V Electromagnetic Lock for Cabinet Access
Landa Ml0180 DC 12V/24V 180kg/350lbs Hidden Electromagnetic Lock for Sercurity System
Sourcing guidance for Electromagnetic Lock
What are the key technical specifications to consider when selecting an electromagnetic lock for commercial use?
When sourcing electromagnetic locks (maglocks), the most critical factor is the Holding Force, which typically ranges from 300 lbs (150kg) for cabinets to 1,200 lbs (550kg) for high-security perimeter doors. You must also verify the Operating Voltage, ensuring the device supports 12V/24V DC dual voltage to match existing access control systems. Additionally, prioritize units with Built-in Hall Effect Sensors (Magnetic Bond Sensors) to provide real-time feedback on whether the door is actually locked, rather than just powered.
Which international compliance standards are mandatory for electromagnetic locks in global markets?
For the North American market, ensure the products are UL 10C listed (for fire-rated doors) and comply with ANSI/BHMA A156.23 standards. For the European market, CE marking and EN 1155 certification are essential. Since these locks are 'Fail-Safe' (unlock when power is lost), they must be integrated with the building's Fire Alarm System to ensure immediate release during emergencies, adhering to local Life Safety Codes.
How can I ensure the durability and longevity of the lock in high-traffic or outdoor environments?
For outdoor applications, you must specify IP66 or IP68 waterproof ratings and a stainless steel housing to prevent corrosion. To ensure longevity, look for locks with Anti-Residual Magnetism features (such as a kick-off button on the armature plate) to prevent the door from sticking after power is cut. Furthermore, verify that the Internal MOV (Metal Oxide Varistor) Surge Protection is included to shield the lock and controller from voltage spikes.
Cross-Border Procurement & Risk Management for Security Hardware
What are the primary risks when importing electromagnetic locks and how can they be mitigated?
The primary risk is Magnetic Interference during air freight, which can affect aircraft instruments. Ensure the supplier uses Magnetic Shielding Packaging and provides a Magnetic Test Report if shipping by air. Another risk is Weight-to-Freight cost ratios; since maglocks are heavy (solid steel/iron), Sea Freight (LCL/FCL) is significantly more economical than air express for bulk orders.
How should I negotiate with suppliers on Made-in-China.com to ensure quality and transaction security?
Always prioritize Audited Suppliers on Made-in-China.com who have undergone third-party on-site inspections. When negotiating, request a Sample Order to test the actual holding force with a tension meter. Use Secured Trading Services offered by the platform to ensure payment is only released after the Bill of Lading (B/L) is verified or a Pre-shipment Inspection (PSI) is completed by a firm like SGS or Intertek.
What shipping and customs precautions should be taken for electromagnetic locks?
Ensure the supplier provides the correct HS Code (typically 8301.30 or 8301.40) to avoid customs delays or incorrect duty applications. Because these are security products, some regions require a Declaration of Conformity. For shipping to the US or EU, confirm that the Armature Plate and Mounting Kits are included in the weight calculation to avoid unexpected 'Dimensional Weight' surcharges from carriers like DHL or FedEx.