Double fire door
I have found results from200000+products and80000+suppliers aboutDouble fire door
Premium Fire Rated Double Door for Heat Insulation and Soundproofing
En Certificated Zhtdoors Factory Price China Supplier Double Steel Industrial Fire Proof Rated Metal Doors Fire Raded Doors
Metal Door Fireproof Double Open Steel Fire Rated Door
Double-Layer Flexible Doors for Extreme Temperatures and Fire Safety
Premium Pre-Hung Double Fire Door Set with Wood Finish
Kdsbuilding Fire Rated Black Design Customized Internal Double Leaf Steel Door
Swing Hospital Emergency Customized Foshan, Guangdong, China Fire Proof Double Door
Aluminum Double Swing Casement Glass French Doors Fire Rated Waterproof Patio Door Side Opening Home Office Casement Door
UL Listed Panic Exit Device Fireproof Double Open Metal Fire Door
Elegant Black Walnut Double Fire-Resistant Front Door for Homes
Double Open Cleanroom Fire Door 4-Window Panic Bar for Hospital Evacuation
Most Popular Modern French Style Iron Door Double Swing Window with Fire Prevention
Steel or Wooden Single or Double Folding Fire Doors
Heavy-Duty Galvanized Steel Double Swing Fire Exit Door
Australian Standards Contemporary Double Impact Doors Hurricane Rated Soundproof Double Leaf Doors Double Fire-Rated Swing Doors
Sourcing guidance for Double Fire Door
What are the critical fire resistance ratings and standards for double fire doors?
Double fire doors must adhere to specific fire-resistance ratings, typically ranging from 30, 60, 90, to 120 minutes (FD30 to FD120). It is essential to verify that the products comply with international standards such as UL 10C (US), BS 476-22 (UK), or EN 1634-1 (EU). Ensure the supplier provides valid test reports from accredited laboratories like Intertek or UL to guarantee the door can withstand high temperatures and prevent the spread of flames.
What technical specifications should be prioritized for the door leaf and frame?
The door leaf should ideally be constructed with a galvanized steel skin (minimum 1.0mm thickness) or high-quality fire-rated timber. The internal core must consist of fireproof materials like perlite board, rock wool, or vermiculite. For the frame, ensure a minimum steel thickness of 1.5mm to prevent warping under heat. Additionally, the inclusion of intumescent seals is mandatory, as they expand during a fire to seal gaps and block smoke.
How does the 'double door' configuration affect hardware requirements?
Double doors require a coordinator (door selector) to ensure the leaves close in the correct sequence, maintaining the fire seal. You must specify heavy-duty fire-rated hinges (at least 3-4 per leaf) and a multipoint locking system or panic exit bars if used in public corridors. All hardware must be CE or UL listed; using non-rated hardware will void the fire certification of the entire assembly.
What are the requirements for vision panels in double fire doors?
If the design includes windows, the glass must be fire-rated wired glass or specialized ceramic glass that matches the fire rating of the door itself. The total area of the vision panel is often restricted by local building codes to maintain structural integrity. Ensure the glass is fitted with fire-resistant glazing gaskets to prevent the glass from falling out during thermal expansion.
Cross-Border Procurement & Risk Management for Fire Doors
How can I verify the authenticity of a supplier's fire certifications?
Request the original PDF of the test reports and certificates, then verify the certificate number directly on the issuing body's website (e.g., the UL Online Certifications Directory). Be wary of suppliers who only provide 'factory certificates' without third-party validation. For high-volume orders, consider hiring a third-party inspector like SGS or TÜV to perform a factory audit and witness a random sample test.
What are the key considerations for shipping and protecting double fire doors?
Fire doors are heavy and prone to edge damage. Insist on reinforced wooden crate packaging rather than just cardboard. Ensure the supplier uses corner protectors and moisture-proof wrapping to prevent rust on steel components during sea freight. When calculating shipping costs, account for the high weight-to-volume ratio, which may necessitate FCL (Full Container Load) shipping to reduce the risk of damage compared to LCL (Less than Container Load).
How should I negotiate quality assurance and after-sales terms with Chinese suppliers?
Utilize Made-in-China.com's Secured Trading services to protect your payment until the goods pass inspection. Negotiate a warranty period of at least 2-5 years on the structural integrity and fire-resistant properties. Clearly define the Acceptable Quality Limit (AQL) in the contract, specifically mentioning that any door failing a smoke-seal or latching test upon arrival will be replaced at the supplier's expense.
What are the common pitfalls regarding international trade policies for construction materials?
Check for anti-dumping duties on steel products in your specific country, as these can significantly increase the total cost of ownership. Ensure the HS Code (typically 7308.30 for steel doors) is correctly declared to avoid customs delays. Always request a Certificate of Origin to potentially benefit from preferential tariff rates under bilateral trade agreements.