Dc surge protector price
I have found results from20000+products and10000+suppliers aboutDc surge protector price
IP67 N Connector RF Coaxial Lightning Arrester DC to 3GHz Base Station Surge Protector
1000V DC Surge Protector, Solar DC SPD Surge Arrester, Photovoltaic SPD, 2p, Lyd1-PV
Reliable T2 Type SPD 1000V DC Surge Protector for Solar Systems Industrial Equipment
500V 600V 1000V 20ka 2p Solar DC SPD Arrester Surge Protector Device
Factory Price Solar System Protection Device 385V 20ka DC Surge Protector
3p Solar Energy PV Surge Protector SPD 3p DC SPD 1500V 20/40ka 4.5kv Arreste
Factory Price DC Xlspd-PV Type 1+2 PV DIN Rail Arrester SPD Surge Protector
Advanced 500V DC Surge Protector for Solar Energy Systems
Advanced 1200V DC Surge Protector for Solar Energy Systems
Tomzn SPD DC 500-1000V 20ka~40ka House Surge Protector Protective Low-Voltage
2p 3p 40ka 1000V DC Solar SPD Surge Protector Device for Lightning Protection
OEM RS485 Signal SPD Control Signal Lightning Protector 12V DC Surge Protector
Good Price Surge Suppressor Metal Oxide Gapless Polymeric Surge Protector 15kv 10ka 5ka
Lighting Arrester Electrical DC SPD Surge Protector Photovoltaic Solar System Protective Device
Thunder Protector Lightning DC Surge Protective Device Photovoltaic Arrester Electrical Solar System
IP20 Outdoor DC Lightning Arrestor 1000V 20~40ka Two Pole Solar Surge Protector
CE PV 4 Pole 20ka-40ka DC 440V SPD Power Surge Protector
Sourcing guidance for Dc Surge Protector Price
What technical specifications determine the price and quality of a DC Surge Protector?
The price is primarily driven by the Maximum Discharge Current (Imax) and Nominal Discharge Current (In). For solar PV systems, ensure the device has a Ucpv (Maximum Continuous Operating Voltage) that exceeds your system's open-circuit voltage by at least 20%. High-quality units utilize Metal Oxide Varistors (MOV) with thermal disconnectors to prevent fire hazards, which may increase the initial cost but ensure long-term system safety.
Which compliance standards are mandatory for international B2B sourcing of DC SPDs?
Buyers must verify that products comply with EN 50539-11 (specifically for PV systems) or IEC 61643-31. For the North American market, UL 1449 4th Edition certification is essential. Sourcing products with CE, TUV, or RoHS markings ensures the protector meets rigorous safety and environmental requirements, reducing the risk of customs seizures or liability issues.
How does the response time (tA) affect the performance and value of the protector?
A professional-grade DC SPD should have a response time of less than 25 nanoseconds. Faster response times provide better protection for sensitive components like inverters and charge controllers. While ultra-fast SPDs carry a premium price, they are economically feasible when compared to the high cost of replacing a damaged solar inverter.
What are the usage scenarios that require specific DC Surge Protector types?
For utility-scale solar farms, Type 1 SPDs are required to handle direct lightning strikes. For residential rooftop PV or telecommunication base stations, Type 2 SPDs are generally sufficient. Choosing the correct Type (Class I, II, or III) based on the lightning risk zone (LPZ) is critical to avoid over-spending on unnecessary specs or under-protecting the equipment.
Cross-Border Procurement & Risk Management for DC SPDs
How can I mitigate the risk of purchasing counterfeit or sub-standard electrical components?
Always request a Type Test Report from an independent third-party lab (like Intertek or SGS). When sourcing via Made-in-China.com, prioritize Audited Suppliers who have undergone on-site factory inspections. Use Trade Assurance services to ensure that the products received match the technical data sheets provided during negotiation.
What are the key strategies for negotiating prices with DC SPD manufacturers?
Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate based on volume tiers; for instance, increasing an order from 100 to 500 units can often yield a 15-25% discount. Additionally, ask for spare modules (pluggable cartridges) to be included in the bulk price, which reduces future maintenance costs.
What logistics and shipping precautions should be taken for sensitive electrical protectors?
DC SPDs contain sensitive internal components that can be damaged by extreme vibration or moisture. Ensure the supplier uses anti-static packaging and moisture-proof vacuum sealing. For shipping to regions with high humidity, specify the use of silica gel desiccant packets inside the master cartons to prevent oxidation of the copper terminals.
How do international trade policies and tariffs affect the final landed cost?
Check the HS Code (typically 8536.30) for your specific country to calculate import duties. Be aware of Anti-Dumping Duties that may apply to electrical components in certain regions. Requesting a Certificate of Origin (Form E or Form F) from the supplier can often help you qualify for preferential tariff rates under Free Trade Agreements.





























