Colony counter
I have found results from3000+products and900+suppliers aboutColony counter
Desktop Electronic Automatic Laboratory Colony Meter Counter Digital Wit Factory Price Cc-J3
High-Precision Semi-Automatic Colony Counter with Bright LED Display
Laboratory Semi-Automatic Accurate Bacterial Colony Counter
Hke-Acc-02 High Definition Automated Automatic Colony Counters for Laboratory Automatic Colony Counter Price
Hke-Acc-01 Intelligent Automatic Colony Counter
Automatic Colony Counter with Cfu Analysis for Petri Dish Hke-Acc-02
Automatic Colony Counter for Microbiology Laboratory Testing Equipment Hke-Acc-03
SCITEK 60-110 mm Automated Bacterial Colony Counter
Desktop Type Colony Counter Automatic Lab Digital Bacterial Counter
Biobase China Bacterial Colony Counter with CMOS Integrated Circuit and LED Digital Display for Laboratory Bc-50
Biobase W 0~9999 Digital Bacterial Colony Counter 5X/10X Amplification Microbiology Manual Colony Counter
Biobase China Bc-50 Automatic Bacterial Colony Counter for Lab
Factory Automatic Colony Counter for Colony Count-Digital Colony Counter-Lab Equipment
Colonometer Automatic Digital Colony Counter for Laboratory
Biobase Digital High Accuracy Bacterial Colony Counter Bc-50 for Lab and Hospital
Hc-B092 Portable Hot Sale Automatic Wireless Digital Colony Counter for Lab
Hot Sale Automatic Portable Colony Counter for Lab/Colony Counter with Low Price
Desktop Type Colony Counter Lab Digital Bacterial Counter
Laboratory Digital Bacterial High-Tech Colony Counter
Ec Laboratory Portable Colony Counter J-2 Easy to Use with Cheap Price
Laboratory Use Digital Colonometer/ Automatic Colony Meter Test 90mm Colony Counter
Biobase CMOS Integrated Circuit Digital Automatic Colony Counter Lab Supplies
Colony Counter Digital Display Automatic Bacterial Examination Device
Sugold Jl-2 Electric Table Type Digital Microbiological Colony Counter with LED
Colony Counter Bacterial Testing Equipment Semi-Automatic Colony Counter
Sourcing guidance for Colony Counter
What are the key technical specifications to consider when selecting a colony counter for laboratory use?
When evaluating a colony counter, prioritize the magnification range (typically 3x to 9x) and the illumination system. High-quality units should feature adjustable LED circular lighting to ensure shadow-free observation. Additionally, verify the counting capacity (usually 0-999 or 0-9999) and ensure the device has an automatic compensation/reset function. For digital models, the pressure sensitivity of the counting pen is crucial; it should trigger a count with a light touch to prevent agar damage while providing an audible confirmation beep.
How do I ensure the colony counter meets international compliance and safety standards?
B2B buyers must verify that the equipment carries CE certification for electrical safety and electromagnetic compatibility. For laboratories operating under strict regulatory frameworks, ensure the supplier provides ISO 9001 certification for manufacturing quality. If the data is used for official reporting, the device should support GLP (Good Laboratory Practice) requirements, including data export capabilities (USB or RS232 interfaces) to maintain unalterable electronic records.
What is the difference between manual, semi-automatic, and fully automatic colony counters in terms of procurement value?
Manual counters are the most cost-effective for low-volume labs, focusing on ergonomic design and basic tallying. Semi-automatic models offer better pressure-sensitive electronic recording, reducing human error. Fully automatic image-analysis systems represent a higher capital investment but provide high-throughput processing, capable of counting hundreds of plates per hour with software-based species differentiation, which significantly reduces long-term labor costs for large-scale food testing or pharmaceutical labs.
What environmental and maintenance factors affect the longevity of the device?
The device should have a corrosion-resistant housing (such as high-grade ABS or stainless steel) to withstand frequent disinfection with alcohol or germicides. Ensure the counting plate is made of high-transparency glass that is scratch-resistant. Maintenance-wise, look for suppliers that provide replaceable counting pens and long-life LED bulbs (rated for >20,000 hours) to minimize downtime and total cost of ownership.
Cross-Border Procurement & Risk Management for Laboratory Equipment
What are the primary risks when sourcing colony counters internationally?
The main risks include voltage incompatibility and shipping damage to sensitive optics. Always specify the required voltage (110V vs 220V) and plug type before production. To mitigate breakage, insist on double-layered foam packaging and wooden crate reinforcement for bulk shipments. Furthermore, use Made-in-China.com's Secured Trading services to ensure payment is only released after the goods pass initial quality inspections.
How can I negotiate better terms with laboratory equipment suppliers?
Focus on bundled procurement; if you need petri dishes, incubators, or pipettes, sourcing them from a single supplier can lead to discounts of 10-15%. Request a spare parts kit (extra pens and fuses) to be included in the initial price. For long-term partnerships, negotiate a 12-24 month warranty period instead of the standard 6 months to ensure post-purchase security.
What logistics and customs considerations apply to scientific instruments?
Colony counters are classified under HS Code 9027 (Instruments for physical or chemical analysis). Ensure the supplier provides a detailed Commercial Invoice, Packing List, and Certificate of Origin to facilitate smooth customs clearance. For urgent laboratory needs, Air Freight is recommended to reduce vibration exposure, though LCL (Less than Container Load) sea shipping is more economical for large-scale distribution orders.





























