Chlorine electrode
I have found results from9000+products and2000+suppliers aboutChlorine electrode
CS5730C Residual chlorine electrode Three-electrode method
ORP Electrode for Chlorine and Sodium Hypochlorite Applications
Effective Chlorine Production: 25g/H, Replacement Electrodes for Salt Chlorinator
Replacement of Electrodes in The Salt Chlorinatoreffective Chlorine Production: 25g/H
The Titanium Electrode Set of The Salt-Chlorine Cell (Anode *7) , Customization
Titaniium Anode (DSA) , Custom Mmo-Coated Titanium Electrode Plates for Salt Chlorine Generators
Reliable Erun-K6b Chlorine Detection Electrode for Industrial Applications
Brine Electrolysis Mmo Coated Titanium Electrode for Chlorine Gas Production
Industrial Precision Residual Chlorine Detector Residual Chlorine Electrode
Hho Generator Titanium Anode Titanium Electrode for Chlorine Generator Coated Ruthenium Iridium Long Working Life
Pcl-1-01 Chloride Ion Selective Electrode Residual Chlorine Testing in Water Purifier
Advanced Chlorine Selective Electrode with Re-Cl Modulator Technology
Digital Online Residual Chlorine Controller Electrode Type for Drinking Water
Residual Chlorine Electrode for Online Water Quality Controller Analyzer
Online Residual Chlorine Controller Electrode Method for Water Treatment
Water Treatment Cl-2059-01 Online Residual Chlorine Electrode
Swimming Pool Online Residual Chlorine Electrode (CL-2059-01)
Outstanding Durability Free Chlorine Electrode for Harsh Wastewater Environments
Online Hot Water Free Chlorine Electrode with Analog Dosing Control for Disinfection
Chemical Resistant Residual Chlorine Electrode Online Analyzer for Polluted Process Water
Low Cost Free Chlorine Electrode for Municipal Wastewater Effluent Monitoring
Sourcing guidance for Chlorine Electrode
How to choose the right type of Chlorine Electrode for different water treatment scenarios?
Selecting the correct electrode depends heavily on the chemical state of the chlorine you need to measure. For Residual Free Chlorine in drinking water or swimming pools, Amperometric sensors are preferred due to their high sensitivity and fast response time. If you are dealing with wastewater or cooling towers where chloramines are present, you must specify a Total Chlorine Electrode. Additionally, consider whether you need a membrane-covered sensor, which reduces interference from flow rate fluctuations, or a potentiostatic electrode for high-precision industrial process control.
What technical specifications are critical for ensuring measurement accuracy and longevity?
Buyers should prioritize electrodes with integrated temperature compensation (PT100/PT1000), as chlorine readings are highly sensitive to temperature shifts. Ensure the pH compensation range is clearly defined, typically between pH 4.0 and 9.0, as the ratio of HOCl to OCl- changes with acidity. Look for sensors with gold or platinum cathodes and silver/silver chloride anodes to ensure electrochemical stability. For long-term durability, verify the electrolyte refillability and the ease of membrane cap replacement.
What compliance and quality standards should a professional Chlorine Electrode meet?
To ensure safety and reliability in international markets, the product should ideally carry CE certification for electronic components and RoHS compliance for hazardous substances. For applications involving potable water, look for materials that meet NSF/ANSI 61 standards or equivalent food-grade certifications. Manufacturers should operate under ISO 9001 quality management systems to guarantee batch-to-batch consistency in sensitivity and slope.
How does the installation environment affect the choice of electrode housing and connection?
The housing material must be chemically resistant; PVC, POM, or Stainless Steel (316L) are standard for corrosive environments. Check the IP68 waterproof rating if the sensor will be submerged. Regarding connectivity, ensure the output signal is compatible with your existing controller—common standards include 4-20mA analog signals or RS485 Modbus RTU digital protocols, the latter being superior for long-distance transmission without signal loss.
Cross-Border Procurement Risks and Strategic Advice for Chlorine Electrodes
What are the primary risks when shipping Chlorine Electrodes internationally?
The most significant risk is the leakage or freezing of the internal electrolyte solution during air freight. Ensure the supplier uses vacuum-sealed protective caps and robust internal padding. Furthermore, because electrodes are precision instruments, they are sensitive to extreme temperature fluctuations in shipping containers; always request temperature-controlled logistics or avoid shipping during peak winter/summer months for sensitive membrane-based sensors.
How can buyers verify supplier credibility and product quality before bulk purchasing?
Request a calibration certificate and a stability test report for the specific batch. A professional supplier on Made-in-China.com should be able to provide a video of the factory's laboratory showing the electrode's response time in standard buffer solutions. It is highly recommended to order a single sample unit for a 30-day field trial to test for drift and polarization time before committing to a large-scale contract.
What negotiation strategies should be used for B2B chlorine sensor procurement?
Focus the negotiation on the Total Cost of Ownership (TCO) rather than just the unit price. Ask for volume-based discounts on consumables like replacement membranes and electrolyte solutions, which are recurring costs. Negotiate for a warranty period of at least 12 months, and clarify the replacement policy for DOA (Dead on Arrival) units, ensuring the supplier covers the return shipping costs for defective items.
How to ensure transaction security and alignment with international trade policies?
Utilize Trade Terms like FOB or CIF to clearly define the point of risk transfer. For payment security, use the secured payment services provided by Made-in-China.com to ensure funds are only released upon proof of shipment. Additionally, verify the HS Code (typically 9027.90) with your local customs broker to accurately calculate import duties and ensure the product meets your country's specific electronic waste (WEEE) regulations.