SourcingAI

Oral medical devices

I have found results from80000+products and20000+suppliers aboutOral medical devices

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: X-Ray Equipment
Type: Catheter
Type: Dental Unit
Type: Imaging System
Type: Interdental Toothbrush
Type: Implant Equipment
Cleaning & Filling Teeth Equipments
Pressure Steam Sterilization Equipments
Ethylene Oxide Sterilization
Condition: New
Application: Adult
Nature: Specialized Equipment
Feature: Waterproof
Usage Times: Non-Disposable
Material: PVC
Applicable Departments: Oral Surgery
Certification: CE
Group: Adult
With Logo Printing
Customized: Customized
Interface: 4 Holes
Cold Light Whitening
Foldable: Non-Foldable
Disposable: Non-Disposable
Age Group: Adult
Usage: Travel
Brush Shape: House-Shaped
Brush Hardness: Soft
Quality Guarantee Period: Two Years
Medical Device Regulatory Type: Type 3
Theory: Pressure Steam
Electric Tension: 220V
With LCD Display
Ultra High Temperature Alarm
Sterilization Information Recording and Printing
Application: Child
Specialized Instrument Equipment
Feature: Anti-Static
Feature: Eco-friendly
Material: Non-woven Fabric
Material: Metal
Material: Iron
Material: Aluminum
Material: Steel
Material: Plastic
Material: Stainless Steel
Oral Department of Internal Medicine
Oral Health Department
Oral Rehabilitation Department
Certification: ISO
Certification: RoHS
Certification: ISO13485
Certification: FDA
Certification: EEC
Usage: Hotel
Usage: Home
Quality Guarantee Period: One Year

Sourcing guidance for Oral Medical Devices

What are the essential regulatory compliance standards for importing oral medical devices?

Oral medical devices are strictly regulated. You must ensure suppliers hold ISO 13485 certification for medical device quality management systems. Depending on the target market, products must have CE Marking (MDR 2017/745) for the EU or FDA 510(k) clearance for the US. Additionally, verify that the manufacturer is registered with their local National Medical Products Administration (NMPA) for export clearance.

How should I evaluate the material safety and biocompatibility of dental instruments?

All materials in contact with the oral cavity must pass ISO 10993 biocompatibility testing, including cytotoxicity, sensitization, and irritation tests. For metal instruments, prioritize medical-grade stainless steel (e.g., 304 or 316L) or titanium alloys to ensure corrosion resistance during repeated autoclave sterilization cycles (typically 134°C).

What technical specifications are critical for electronic oral devices like dental handpieces or scalers?

Focus on rotation speed stability, noise levels (ideally <60dB), and torque consistency. For cordless devices, check battery capacity (mAh) and charging safety standards. Ensure the electrical components comply with IEC 60601-1 (medical electrical equipment safety) to prevent electrical shocks or electromagnetic interference in a clinical environment.

Can I request customization (OEM/ODM) for oral medical devices?

Yes, most professional manufacturers on Made-in-China.com offer OEM services. This includes laser-marking your logo on stainless steel tools, custom packaging design, and even modifying molds for ergonomic handles. However, ensure that any design changes do not invalidate existing clinical trial reports or regulatory certifications.

Cross-Border Procurement Strategy & Risk Management

How can I mitigate the risk of receiving sub-standard medical equipment?

Always request a Pre-Shipment Inspection (PSI) conducted by a third-party agency like SGS or Intertek. Specifically, ask for a Functionality Test and a Sterility Barrier Integrity Test. Using Secured Trading Services on Made-in-China.com can also protect your payment until the goods are verified against your technical specifications.

What are the best practices for negotiating with dental supply manufacturers?

Don't just negotiate on unit price; negotiate on warranty terms (minimum 12-24 months) and the provision of free spare parts (e.g., O-rings, bearings). For long-term partnerships, request a Quality Agreement that defines the acceptable quality limit (AQL) and the supplier's liability for defective batches.

What shipping precautions are necessary for sensitive medical electronics?

Oral scanners and electronic units require anti-static packaging and shock-absorbent cushioning. Ensure the outer cartons are marked with 'Fragile' and 'Keep Dry' symbols. For sea freight, use desiccants to prevent moisture damage to precision mechanical parts. Confirm if the supplier can provide Door-to-Door (DDP) shipping to simplify customs clearance for medical goods.

How do I verify the authenticity of a supplier's medical certifications?

Cross-reference the certificate number on the official website of the issuing body (e.g., the NANDO database for CE or the FDA Establishment Registration database). On Made-in-China.com, look for 'Audited Suppliers' who have had their business licenses and production capabilities verified by independent inspection companies.

Related queries