SourcingAI

Breaker switch

I have found results from200000+products and80000+suppliers aboutBreaker switch

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: High-voltage
Type: Circuit Breaker
Type: Low-voltage
Type: Normal Open
Type: Fuse
Certification: ISO9001
Shell Material: Stainless Steel
Voltage Level: Medium Voltage
Installation: Fixed
Structure: Cabinet
Current: DC
Operation: Electric
Grounding Mode: Grounding
Movement Mode: Oscillating Type
Number of Poles: Three Pole
Grounding: Single Ground
Series: Two
Turn the Horizontal
Switching Mode: Single Throw-in
Structure of Operating: Electric
Common Model: YR
Low Voltage Circuit Breakers
Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Conventional Circuit Breaker
Single Control Switch
Size: Normal Size
Environment: ﹤250℃
Breaking Form: Single Type
Condition: New
Poles Number: 4
Protection: Durable
Feature: Rocker
Null Line and Live Line
Principle: Capacitive
Application: Home Appliance
Usage: Control Button
Single-pole on-off Switch
Standard: Standard
Lamp: With Lamp
Warranty: 1 Year
Output type: Dual
Certification: ISO
Certification: IS9001
Certification: CE
Certification: VDE
Certification: CCC
Certification: GS
Certification: RoHS
Certification: ISO9002
Certification: ISO2000
Certification: ISO9001-2000
Certification: CB
Installation: Outdoor High-voltage
Installation: Insert
Installation: Vertical
Installation: Indoor High-voltage
Structure: Three-column Disconnector
Structure: Double-column Disconnector
Structure: Single-column Disconnector
Structure: MCB
Power Built-in Type
Current: AC
Operation: Manual
Operation: Manual Type
Operation: Electric Type
Grounding Mode: Not Grounding
Vertical Rotary Type
Movement Mode: Plug-in Type
Horizontal Rotary Type
Grounding: Un Grounded
Grounding: Double Ground
Series: Three
Series: Single-Stage
Run: Vertical Rotation
Run: Swing
Run: Plug-In
Switching Mode: Double-Throw Type
Structure of Operating: Manual
Structure of Operating: Pneumatic
Common Model: SR
Breaking Capacity: General Type
High Voltage Circuit Breakers
High-Speed Circuit Breaker
Arc-extinguishing Medium: SF6
Arc-extinguishing Medium: Oil-immersed Type
Arc-extinguishing Medium: Vacuum
Circuit-Breaker Failure Protection
Function: Overcurrent Protection
Function: OVP(Overvoltage Protection)
Function: RCCB
Poles Number: 3
Poles Number: 1
Application: Electronics
Application: Lighting
Application: Industrial
Application: Apartment/Villa
Application: Hotel
Application: Commercial
Application: Home
Usage: Start Button
Usage: Control Switch
Usage: Electrical Appliance

Sourcing guidance for Breaker Switch

What are the key technical specifications to consider when selecting a Breaker Switch?

When sourcing breaker switches, you must prioritize Rated Current (In) and Rated Voltage (Un) to ensure they match your electrical system's load. Additionally, the Breaking Capacity (Icu/Ics) is critical; it must be high enough to safely interrupt the maximum potential fault current. For industrial applications, look for Magnetic and Thermal Trip settings that are adjustable to provide precise protection against overloads and short circuits.

Which international compliance standards are mandatory for Breaker Switches?

Compliance is non-negotiable for safety components. Ensure the products meet IEC 60947-2 for industrial circuit breakers or IEC 60898-1 for household applications. For specific markets, verify CE marking (Europe), UL listing (North America), or CCC certification (China). Always request valid test reports from accredited third-party laboratories to confirm these certifications are not forged.

How do I evaluate the mechanical and electrical durability of a Breaker Switch?

Check the manufacturer's datasheet for Mechanical Life (number of no-load operations) and Electrical Life (number of operations under load). High-quality breakers typically offer at least 10,000 to 20,000 mechanical cycles. Furthermore, ensure the housing is made of flame-retardant materials (UL94-V0 grade) to prevent fire hazards during a malfunction.

What are the common usage scenarios for different types of Breaker Switches?

Miniature Circuit Breakers (MCB) are ideal for low-voltage residential and light commercial use. Molded Case Circuit Breakers (MCCB) are better suited for higher current industrial circuits, while Air Circuit Breakers (ACB) are used in large power distribution systems. For personnel protection against electric shock, always integrate Residual Current Circuit Breakers (RCCB/RCBO).

Cross-Border Procurement Risks and Strategies for Breaker Switches

How can I mitigate the risk of purchasing counterfeit or sub-standard electrical components?

Always conduct a factory audit or hire a third-party inspection service like SGS or Intertek. On Made-in-China.com, prioritize Audited Suppliers who have undergone on-site verification. Request material safety data sheets (MSDS) and verify the authenticity of the brand's holographic labels or serial numbers directly with the manufacturer.

What are the best practices for negotiating with Breaker Switch suppliers?

Focus on the Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for extended warranties (24-36 months) and ask for spare parts (e.g., auxiliary contacts or shunt trips) to be included in bulk orders. For long-term partnerships, request price protection clauses to hedge against fluctuations in raw material costs like copper and silver.

What shipping precautions should be taken for sensitive electrical equipment?

Breaker switches contain sensitive internal mechanisms. Ensure the supplier uses moisture-proof packaging (vacuum sealing or silica gel packets) and shock-absorbent padding. For sea freight, specify FCL (Full Container Load) when possible to reduce handling risks, and ensure the outer cartons are marked with 'Fragile' and 'Keep Dry' international symbols.

How do I ensure transaction security in international trade?

Utilize Secured Payment services provided by reputable platforms like Made-in-China.com to ensure funds are only released upon confirmation of shipment. Use Incoterms 2020 clearly in your contract (e.g., FOB or CIF) to define the exact point where risk transfers from the seller to the buyer, and always obtain Marine Cargo Insurance.

Related queries